Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique

Eur Radiol. 2012 Aug;22(8):1613-23. doi: 10.1007/s00330-012-2452-z. Epub 2012 Apr 27.

Abstract

Objectives: To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR).

Methods: One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test.

Results: Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 ± 3.00) than low-dose ASIR (49.24 ± 9.11, P < 0.01) and reference-dose ASIR images (24.93 ± 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability.

Conclusion: Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality.

Key points: • Model-based iterative reconstruction (MBIR) creates high-quality low-dose CT images. • MBIR significantly improves image noise and artefacts over adaptive statistical iterative techniques. • MBIR shows greater potential than ASIR for diagnostically acceptable low-dose CT. • The prolonged processing time of MBIR may currently limit its routine use in clinical practice.

MeSH terms

  • Aged
  • Algorithms
  • Artifacts
  • Body Weight
  • Diagnostic Imaging / methods
  • Female
  • Humans
  • Lung / diagnostic imaging
  • Male
  • Middle Aged
  • Models, Statistical
  • Motion
  • Phantoms, Imaging
  • Prospective Studies
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Reproducibility of Results
  • Tomography, X-Ray Computed / methods*