Assessing PaCO2 in acute respiratory disease: accuracy of a transcutaneous carbon dioxide device

Intern Med J. 2011 Aug;41(8):630-3. doi: 10.1111/j.1445-5994.2010.02213.x. Epub 2010 Feb 26.

Abstract

Background: Pulse oximetry non-invasively assesses the arterial oxygen saturation of patients with acute respiratory disease; however, measurement of the arterial partial pressure of carbon dioxide (PaCO(2)) requires an arterial blood gas. The transcutaneous partial pressure of carbon dioxide (PtCO(2) ) has been used in other settings with variable accuracy. We investigated the accuracy of a PtCO(2) device in the assessment of PaCO(2) in patients with asthma and suspected pneumonia attending the emergency department.

Methods: Patients with severe asthma (FEV(1) < 50% predicted) or suspected pneumonia (fever, cough and respiratory rate >18/min) were enrolled. Subjects were excluded if they had a history of chronic obstructive pulmonary disease or other conditions associated with respiratory failure. Arterial blood gases were taken at the discretion of the investigator according to clinical need, and paired with a simultaneous reading from the PtCO(2) probe.

Results: Twenty-five patients were studied with one set of data excluded because of poor PtCO(2) signal quality. The remaining 24 paired samples comprised 12 asthma and 12 pneumonia patients. The range of PaCO(2) was 19-64 mmHg with a median of 36.5 mmHg. Bland-Altman analysis showed a mean (SD) PaCO(2) - PtCO(2) difference of -0.13 (1.9) mmHg with limits of agreement of plus or minus 3.8 mmHg (-3.9 to +3.7).

Conclusion: A PtCO(2) device was accurate in the assessment of PaCO(2) in patients with acute severe asthma and suspected pneumonia when compared with an arterial blood gas. These bedside monitors have the potential to improve patient care by non-invasively monitoring patients with acute respiratory disease at risk of hypercapnia.

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acute Disease
  • Adult
  • Asthma / blood*
  • Asthma / diagnosis
  • Blood Gas Monitoring, Transcutaneous / methods
  • Blood Gas Monitoring, Transcutaneous / standards
  • Carbon Dioxide / blood*
  • Community-Acquired Infections / blood
  • Community-Acquired Infections / diagnosis
  • Female
  • Humans
  • Male
  • Oximetry / methods
  • Oximetry / standards*
  • Partial Pressure
  • Pneumonia / blood*
  • Pneumonia / diagnosis
  • Prospective Studies

Substances

  • Carbon Dioxide