Ruling out clinically suspected pulmonary embolism by assessment of clinical probability and D-dimer levels: a management study

Thromb Haemost. 2003 Jan;89(1):97-103.

Abstract

D-dimer test combined with clinical probability assessment has been proposed as the first step in the diagnostic work-up of patients with suspected pulmonary embolism (PE). In a prospective management study we investigated the safety and efficiency of excluding PE by a normal D-dimer combined with a low or moderate clinical probability. Of the 202 study patients this combination ruled out PE in 64 (32%) patients. The 3-month thromboembolic risk in these patients was 0% (95% CI, 0.0-5.6%). The prevalence of PE in the entire cohort was 29% (59 patients), whereas in the low, moderate and high clinical probability groups this was 25%, 26% and 50%, respectively. We conclude that ruling out suspected PE by a normal D-dimer combined with a low or moderate clinical probability appears to be a safe and efficient strategy. The accuracy of the clinical probability assessment is modest.

Publication types

  • Evaluation Study

MeSH terms

  • Adult
  • Aged
  • Algorithms
  • Diagnosis, Differential
  • Female
  • Fibrin Fibrinogen Degradation Products / analysis*
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Prevalence
  • Probability
  • Pulmonary Embolism / diagnosis*

Substances

  • Fibrin Fibrinogen Degradation Products
  • fibrin fragment D