Monitoring of haemoglobin oxygen saturation in healthy infants using a new generation pulse oximeter which takes motion artifacts into account

  • Original Paper
  • Published:
European Journal of Pediatrics Aims and scope Submit manuscript

Abstract.

The aim of this study was to establish normal values for overnight oxygen saturation (SpO2) in healthy term infants using an oximeter which takes into account motion artifacts and to compare these to normal values collected with a previous generation oximeter not correcting for motion artifacts. We recorded overnight SpO2 in 26 term, healthy infants (median age 136 days, range 6–364 days) in the home environment using the Nellcor Symphony N 3000 pulse oximeter with an averaging time of 3 s. A sample rate of 5 s was chosen. Motion artifacts were excluded from the analysis. Data were compared with those from a previous study, using the same inclusion and exclusion criteria with the Oxford Medilog. Median (quartiles) SpO2 was 98% (97%–99%). Median percentage of study time below SpO2 94% was 0.2% (0.1%–0.7%); median percentage of study time below SpO2 90% was 0.0% (0.0%–0.01%). Median SpO2 with the Oxford oximeter was 97% (96%–98%); percentage of study time below SpO2 94% was 8% (2%–14%); percentage of study time below SpO2 90% was 2% (0%–4%). These data were compared with the Nellcor Symphony data: differences in median SpO2 were significant (P<0.05); differences in percentage of time below SpO2 94% and 90% were also statistically significant (P<0.001). Conclusion: we established normal values of oxygen saturation in healthy term infants using the Nellcor Symphony 3000 pulse oximeter. Care should be taken in interpreting values obtained with different types of pulse oximeters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Meyts, I., Reempts, P. & Boeck, K. Monitoring of haemoglobin oxygen saturation in healthy infants using a new generation pulse oximeter which takes motion artifacts into account. Eur J Pediatr 161, 653–655 (2002). https://doi.org/10.1007/s00431-002-1089-3

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00431-002-1089-3

Navigation