Skip to main content
Log in

The balloon technique: a convenient method to measure exhaled NO in epidemiological studies

  • ORIGINAL ARTICLE
  • Published:
International Archives of Occupational and Environmental Health Aims and scope Submit manuscript

Abstract

Objectives: The aim of the present study was to evaluate the balloon procedure to measure exhaled nitric oxide (NO). Methods: This was performed by comparing the procedure with the well-established on-line measurement of NO (direct exhalation into the NO module). Using both procedures exhaled NO was measured in 16 healthy subjects on two days with different level of air pollution. Results: Exhaled NO measured on-line was 3.8–4.5 times lower than exhaled NO obtained using the balloon technique but the two sets of values correlated linearly (r 0.93–0.97). Mean NO level on day 1 with low air pollution and day 2 with high air pollution was 6.6 and 8.1 parts per billion (ppb; on-line measurement) and 25.2 and 36.9 ppb (balloon method), respectively. The day 1 to day 2 ratio differed per subject but was independent of the technique of measurement. Mean day-to-day ratio of exhaled NO using the balloon technique (1.65 ± 0.13) was not different (P < 0.05) from the ratio of NO levels measured on-line (1.49 ± 0.13). Based on these ratios the increase in level of outdoor air pollution appears to be associated with a 49–65% increase in exhaled NO. Conclusion: Exhaled NO is proposed as a de novo individual biomarker to monitor the adverse effects of air pollution. The balloon procedure offers a sound and convenient alternative for the on-line procedure to measure exhaled NO in large populations as required in epidemiological studies.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 22 December 1998 / Accepted: 24 April 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

van Amsterdam, J., Verlaan, A., van Loveren, H. et al. The balloon technique: a convenient method to measure exhaled NO in epidemiological studies. Int Arch Occup Environ Health 72, 404–407 (1999). https://doi.org/10.1007/s004200050392

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004200050392

Navigation