Table 9

Ranges, mean, SD, median and IQR values for SpO2 (%) where measurements were made with the patient receiving air for age ≥18 years (n=37 299) from Smith et al19

Age (years)nSpO2
MinimumMaximumMeanSDMedianIQR
18–2416638010098.01.89897–99
25–3422398210097.61.99897–99
35–4434127310097.22.19896–99
45–5441037610096.82.29796–98
55–6450207210096.32.59795–98
≥6520 8627010095.82.79695–98
  • SpO2, arterial oxygen saturation measured by pulse oximetry.