Table 3

 Sensitivity index of spirometry and oscillometry measurements

Change (visit 3–visit 1)Coefficient of variation (%)Sensitivity index
FEV, forced expiratory volume in 1 s; %FL, percentage flow limitation; IC, inspiratory capacity; Rrs, resistance of the respiratory system; VC, vital capacity; Xrs, reactance of the respiratory system.
This analysis uses percentage change rather than percentage predicted values for spirometry in order to be comparable with the coefficient of variation.
Spirometry (% change)
    VC15.57.22.15
    FEV124.89.62.58
    IC16.78.81.90
Oscillometry (% change)
    Rrs−0.9512.20.08
    Xrs35.224.11.46
    Rrs,insp−3.914.00.28
    Xrs,insp27.417.61.56
    Rrs,exp1.2513.20.09
    Xrs,exp37.128.61.30
    %FL−19.513.31.47