Table 3

Test qualities of different ways of expressing a positive bronchodilator response with PEF measurements (ΔPEF absolute with cut off values of 40, 60, and 80 l/min and ΔPEF % baseline with cut off values of 10%, 15%, and 20%) in relation to different references as assessed by spirometric tests (n = 240)

Δ PEF measurementsSensitivitySpecificityPPVNPV
(A) ΔFEV1 ⩾9% predicted
⩾10% baseline56853693
⩾15% baseline44945292
⩾20% baseline25986790
⩾40 l/min53873992
⩾60 l/min28954590
⩾80 l/min13995788
(B) ΔFEV1⩾200 ml absolute
⩾10% baseline41865281
⩾15% baseline27946378
⩾20% baseline16998377
⩾40 l/min35885079
⩾60 l/min18955576
⩾80 l/min 6985775
(C) ΔFEV1⩾12% predicted and 200 ml absolute
⩾10% baseline73821698
⩾15% baseline42933793
⩾20% baseline29985893
⩾40 l/min64841698
⩾60 l/min36932097
⩾80 l/min 9971496
(D) ΔFEV1⩾15% baseline and 200 ml
⩾10%baseline60821897
⩾15% baseline47912696
⩾20% baseline40975096
⩾40 l/min53841896
⩾60 l/min27932095
⩾80 l/min 7971494
  • PPV = positive predictive value; NPV = negative predictive value.