Article Text

other Versions

Correspondence
Thorax editorial by Jenkins and Beasley related to tiotropium respimat
Free
  1. Norbert Metzdorf,
  2. Christoph Hallmann,
  3. Bernd Disse
  1. Department of Clinical Development & Medical Affairs, Boehringer Ingelheim Pharma GmbH & Co KG, Ingelheim, Germany
  1. Correspondence to Dr Norbert Metzdorf, Department of Clinical Development & Medical Affairs, Boehringer Ingelheim Pharma GmbH & Co KG, Binger Strasse 173, Ingelheim 55216, Germany; norbert.metzdorf{at}boehringer-ingelheim.com

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

We thank Drs Jenkins and Beasley for their comments in the recent editorial regarding tiotropium (SPIRIVA)1. Preceding the Singh et al2 analysis cited by the authors, Boehringer Ingelheim (BI) had analysed both the tiotropium HandiHaler and Respimat pooled datasets using patient-level data on-treatment as well as including vital status. The results showed a nominally statistically significant reduction for tiotropium HandiHaler and a numerical increase with tiotropium Respimat compared with the respective placebo group for all-cause mortality.

These results are adequately reflected in the local SPIRIVA product information (http://www.medicines.org.uk/EMC/searchresults.aspx?term=spiriva&searchtype=QuickSearch).

Recently published analyses on tiotropium Respimat data (including the analyses of Dong et al3) were conducted on the same set of clinical data; therefore, they cannot be considered independent evidence, and are all limited by not using patient-level data.

The tiotropium Respimat dose (5 µg once daily) was chosen to match the efficacy and safety of the well-established tiotropium HandiHaler 18 µg. Three pharmacokinetics (PK) studies compared the PK of tiotropium after inhalation from both devices. One study4 found 22% and 35% higher exposures (area under the curve from 0 to 6 h (AUC0-6) and maximum plasma concentration (Cmax)) for Respimat 5 µg versus HandiHaler 18 µg. A second study5 in Japanese patients showed virtually identical plasma levels. A newly available third study,6 with optimised procedures for PK analysis, reported 24% and 19% lower exposures (AUC0-6 and Cmax) for tiotropium Respimat 5 µg versus tiotropium HandiHaler 18 µg. This study also demonstrated similar PK variability for the two tiotropium formulations. Therefore, available data suggest similar systemic exposure for both devices and any apparent difference between formulations remains unexplained and implausible. In order to confirm the hypothesis of no difference between matching formulations, BI is conducting the TIOSPIR study in over 17 000 patients comparing once-daily tiotropium Respimat 5 µg and tiotropium HandiHaler 18 µg with all-cause mortality and COPD exacerbations as co-primary endpoints. A further arm with tiotropium Respimat 2.5 µg is included in order to inform dose selection for future combination products. The study is supervised by an independent Data Safety Monitoring Board (DSMB) with access to fully unblinded data. The DSMB evaluates the most current database every 4 months and has, up to now, recommended to ‘continue as planned’. The study is approaching finalisation in 2013 and has exceeded three-quarters of the number of events used in the power calculation for the primary analysis.

Finally, the patients enrolled in the tiotropium trial programme had a comorbidity profile comparable with the general COPD population (see online supplement).

References

Supplementary materials

  • Supplementary Data

    This web only file has been produced by the BMJ Publishing Group from an electronic file supplied by the author(s) and has not been edited for content.

    Files in this Data Supplement:

Footnotes

  • Contributors All authors conceived, drafted, read and approved the letter.

  • Funding Boehringer Ingelheim Pharma GmbH & Co KG.

  • Competing interests None.

  • Patient consent Obtained.

  • Provenance and peer review Not commissioned; internally peer reviewed.

Linked Articles