Polysomnography (PSG) is recommended for non-invasive ventilation (NIV) set-up in patients with chronic respiratory failure. In this pilot randomised clinical trial, we compared the physiological effectiveness of NIV set-up guided by PSG to limited respiratory monitoring (LRM) and nurse-led titration in patients with COPD–obstructive sleep apnoea (OSA) overlap. The principal outcome of interest was change in daytime arterial partial pressure of carbon dioxide (PaCO2) at 3 months. Fourteen patients with daytime PaCO2 >6 kPa and body mass index >30 kg/m2 were recruited. At 3 months, PaCO2 was reduced by −0.88 kPa (95% CI −1.52 to −0.24 kPa) in the LRM group and by −0.36 kPa (95% CI −0.96 to 0.24 kPa) in the PSG group. These pilot data provide support to undertake a clinical trial investigating the clinical effectiveness of attended limited respiratory monitoring and PSG to establish NIV in patients with COPD–OSA overlap.
Trial number Results, NCT02444806.
- non invasive ventilation
- sleep apnoea
Statistics from Altmetric.com
Introduction
Patients with COPD–obstructive sleep apnoea (COPD–OSA) overlap syndrome have a greater incidence of chronic respiratory failure compared with patients with OSA alone.1 Non-invasive ventilation (NIV) has been demonstrated as an effective treatment2 and current guidelines recommend polysomnography (PSG) accompanied by waveform analysis and retrospective NIV modification on the following day to direct NIV titration.3 However, access to PSG is limited and, combined with a rising numbers of patients requiring investigation for sleep-disordered breathing, clinical capacity is unable to match demand. Simple overnight transcutaneous measurements of gas exchange with nurse-led titration according to a protocol has been used as an alternative to PSG-directed set-up.4–6 The aim of the current study was to determine the physiological efficacy of limited respiratory monitoring (LRM) using transcutaneous oxi-capnometry and nurse-led titration, compared with PSG and retrospective NIV modification, for the set-up of NIV in patients with chronic respiratory failure secondary to COPD–OSA overlap.
Methods
The study protocol was approved by Guy’s and St Thomas’ Research Ethics Committee (14/EM/1257) and the trial registered in a publically accessible database (NCT02444806).
Inclusion and exclusion criteria
Patients naive to home NIV use were recruited if they met the following criteria: diagnosis of COPD as defined by the Global Initiative for Chronic Obstructive Lung Disease criteria,7 OSA defined by a 4% oxygen desaturation index >7.5 events/hour or an apnoea–hypopnoea index >5 events/hour, a daytime arterial PaO2 of carbon dioxide (PaCO2) >6 kPa and a body mass index (BMI) >30 kg/m2. Exclusion criteria included decompensated respiratory failure with a pH <7.35, inability to tolerate NIV (<4 hours usage during titration), contraindication to NIV, pregnancy, age <18 years and any significant physical or psychiatric comorbidity that would prevent adherence to the trial protocol. Patients were randomised 1:1 to have NIV set-up using LRM or PSG. All overnight titrations in the PSG arm were performed by a single specialist trained respiratory physician. In the LRM arm, the overnight NIV titration was performed by a specialist trained nurse from the ward clinical team, which was not always the same member of staff. Final assessment was performed 3 months after NIV set-up.
Outcomes
Principal outcome of interest was daytime arterial partial pressure of carbon dioxide (PaCO2) at 3 months. Other relevant outcomes were daytime PaO2, adherence to ventilation (measured hours of use recorded by device software), health-related quality of life (measured by severe respiratory questionnaire; SRI), sleep quality (measured by Pittsburgh Sleep Quality Index; PSQI) and physiological efficacy of NIV demonstrated by change in neural respiratory drive.
Full methodology including the nurse-led titration protocol and NIV modification protocol and statistical analysis plan have been placed in the online (supplementary material and methods, pages 1–4 OLS; figure E1, page 9 OLS).
Supplemental material
Results
Baseline
Recruitment was performed between 25 February and 7 November 2015. Forty-two patients were screened for study participation and 14 included (online supplementary figure E2, page 10 OLS). No patients withdrew or were lost to follow-up. Three (43%) patients in each group were established on long-term oxygen therapy. Baseline characteristics are shown in table 1. Length of stay for baseline assessments and NIV set-up was similar between both groups; 2 (2-2) nights in the LRM arm versus 2 (2-3) nights in the PSG arm. NIV settings were similar between both groups (table 2). Visual analogue scales of ease of falling asleep, comfort of sleep and comfort of breathing were similar between both groups.
Outcomes of ventilation at 3 months
At trial completion (3 months), there was a reduction in PaCO2 of −0.88 kPa (95% CI −1.52 to −0.24 kPa) in the LRM group and of −0.36 kPa (95% CI −0.96 to 0.24 kPa) in the PSG group. Mean adherence was 4.4 hours/night (95% CI 2.8 to 6.0) in the LRM group and 2.3 hours/night (95% CI 0.91 to 3.8) in the PSG group. Within the 7 days preceding final evaluation, NIV was used for more than 4 hours for 4.7 nights (95% CI 2.7 to 6.7) in the LRM group and 0.7 nights (95% CI 0.0 to 2.4) in the PSG group. Changes in other relevant outcome variables were similar (table 2).
In the overall study population, there was a significant improvement in daytime PaCO2 (mean difference of −0.62 (95% CI −1.02 to −0.22)), in SRI (mean difference 10.8 (95% CI −2.6 to 19.0)), Epworth Sleepiness Scale (mean difference −1.9 (95% CI −3.6 to −0.1)) and PSQI (mean difference −4.3 (95% CI −6.5 to −2.1)).
Results detailing the NIV set-up and the nested physiological study are available in the online supplement (results pages 4–6 OLS).
Discussion
This pilot randomised physiological effectiveness trial demonstrated that LRM using transcutaneous oxi-capnometry and nurse-led NIV titration, in patients with COPD–OSA with chronic respiratory failure, resulted in a greater fall in daytime PaCO2 at 3 months compared with gold-standard PSG monitoring and retrospective NIV modification. The improvements in health-related quality of life and daytime somnolence were in line with previous published data and of a similar magnitude to those achieved in patients with obesity-related respiratory failure.8
Despite randomisation, patients allocated to the PSG-directed titration had more severe COPD–OSA overlap when compared with patients allocated to LRM-directed titration. BMI, neck circumference, smoking history and baseline daytime PaCO2 were all numerically higher in the PSG arm. These differences may have contributed to the higher EPAP in the PSG group, which in turn could be responsible for adverse pulmonary mechanics with reduced respiratory muscle unloading and subsequent poor comfort and reduced adherence. However, the comfort scores at NIV set-up were the same. The lower NIV adherence in the PSG arm may explain, in part, the lower reduction of daytime PaCO2 at follow-up.9 The small sample size of the study prevents the completion of an adjusted analysis to try and account for the differences in NIV adherence or any other baseline differences between the two groups. The results from this pilot proof-of-concept clinical trial need to be interpreted with caution and are hypothesis generating rather than hypothesis testing, which is the role of a multicentre clinical trial.
Despite these limitations, our data support the use of transcutaneous combined oxi-capnometry monitoring, in combination with a nurse-led titration protocol to safely establish NIV in patients with chronic respiratory failure secondary to COPD–OSA overlap syndrome. Both LRM and PSG groups achieved similar clinical effectiveness in terms of change in daytime PaCO2, health-related quality of life and sleep quality. These data support the safety and efficacy of limited respiratory monitoring and nurse-led titration as a simpler alternative approach to PSG for home NIV set-up. The next step will be to proceed to a multicentre clinical trial that will investigate the clinical and cost-effectiveness of limited respiratory monitoring with a nurse-led titration protocol. This is in line with the current direction of home NIV delivery with the use of auto-titrating devices, which have been shown to be safe and effective in patients with COPD–OSA overlap syndrome.6 Indeed, the built-in ventilator software may offer additional data, including Vt, leak flow and volume, triggered breaths10 and residual events.11
Footnotes
Contributors MP: conception of the work, acquisition, analysis, interpretation of data, drafting of the work. GA: acquisition of data, critical revising of the draft. AC, JFM, NH: conception of the work, critical revising of the draft. PBM: conception of the work, acquisition, analysis, interpretation of data, drafting and critical revising of the draft.
Funding MP received a research grant from ADIR association (grant no. ADIR-2014-01).
Competing interests MP reports grants from ADIR Association, from B&D Electromedical, during the conduct of the study; personal fees from Fisher & Paykel and ResMed, non-financial support from Antadir and Asten, outside the submitted work. JFM reports grants from ADIR Association, during the conduct of the study; personal fees from Philips-Respironics, personal fees from ResMed, personal fees from Air Liquide Santé, personal fees from Breas, personal fees from Boehringer, outside the submitted work. NH reports grants from Guy’s and St Thomas’ Charity, during the conduct of the study; grants from Philips-Respironics, non-financial support from Philips-Respironics RT Meeting (MYOTRACE), personal fees from Fisher & Paykel, grants from ResMed, grants from B&D Electromedical, grants from Fisher & Paykel, outside the submitted work. In addition, NH has a patent MYOTRACE pending and MP is on the Pulmonary Research Advisory Board for Philips. NH’s research group has received unrestricted grants (managed by Guy’s and St Thomas’ Foundation Trust) from Philips-Respironics, Philips, ResMed, Fisher & Paykel, and B&D Electromedical. Philips-Respironics are contributing to the development of the MYOTRACE technology. PBM reports grants and personal fees from Philips-Respironics, grants from ResMed, grants from B&D Electromedical, outside the submitted work. Other authors have no competing interests to declare.
Patient consent Obtained.
Ethics approval Guy’s Research Ethics Committee.
Provenance and peer review Not commissioned; externally peer reviewed.
Author note MP is the guarantor of the content of the manuscript, including the data and analysis.
Correction notice This article has been corrected since it was published Online First. A sentence in the Abstract and the Outcome section has been corrected.