Comparison of shuttle walk with measured peak oxygen consumption in patients with operable lung cancer
Free
  1. T Win1,
  2. A Jackson2,
  3. A M Groves3,
  4. L D Sharples4,
  5. S C Charman4,
  6. C M Laroche1
  1. 1Thoracic Oncology Unit, Papworth Hospital, Papworth, Cambridge, UK
  2. 2Respiratory Laboratory, Papworth Hospital, Papworth, Cambridge, UK
  3. 3Radiology and Nuclear Medicine Department, Addenbrooke’s Hospital, Cambridge, UK
  4. 4MRC Biostatistics Unit, Robinson Way, Cambridge, UK
  1. Correspondence to:
    Dr T Win
    Lister Hospital, Stevenage, Hertfordshire SG1 4AB, UK; drthidawin{at}hotmail.com

Abstract

Background: The relationship between the shuttle walk test and peak oxygen consumption in patients with lung cancer has not previously been reported. A study was undertaken to examine this relationship in patients referred for lung cancer surgery to test the hypothesis that the shuttle walk test would be useful in this clinical setting.

Methods: 125 consecutive patients with potentially operable lung cancer were prospectively recruited. Each performed same day shuttle walking and treadmill walking tests.

Results: Shuttle walk distances ranged from 104 m to 1020 m and peak oxygen consumption ranged from 9 to 35 ml/kg/min. The shuttle walk distance significantly correlated with peak oxygen consumption (r = 0.67, p<0.001). All 55 patients who achieved more than 400 m on the shuttle test had a peak oxygen consumption of at least 15 ml/kg/min. Seventy of 125 patients failed to achieve 400 m on the shuttle walk test; in 22 of these the peak oxygen consumption was less than 15 ml/kg/min. Nine of 17 patients who achieved less than 250 m had a peak oxygen consumption of more than 15 ml/kg/min.

Conclusion: The shuttle walk is a useful exercise test to assess potentially operable lung cancer patients with borderline lung function. However, it tends to underestimate exercise capacity at the lower range compared with peak oxygen consumption. Our data suggest that patients achieving 400 m on the shuttle walk test do not require formal measurement of oxygen consumption. In patients failing to achieve this distance we recommend assessment of peak oxygen consumption, particularly in those unable to walk 250 m, because a considerable proportion would still qualify for surgery as they had an acceptable peak oxygen consumption.

  • FEV1, forced expiratory volume in 1 second
  • Kco, carbon monoxide transfer coefficient
  • Tlco, carbon monoxide transfer factor, V˙o2peak, peak oxygen consumption
  • lung function
  • lung cancer
  • shuttle walk test
  • oxygen consumption
  • surgery

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Published Online First 21 October 2005

  • This work received funding from the Research and Development NHS Executive.

  • Competing interests: none.