Complications of fiberoptic bronchoscopy at a university hospital

Chest. 1995 Feb;107(2):430-2. doi: 10.1378/chest.107.2.430.

Abstract

Study objective: To retrospectively review the indications and complications associated with flexible fiberoptic bronchoscopy (FFB) in a university teaching hospital.

Design: retrospective review from April 1, 1988 to March 30, 1993.

Setting: Large tertiary care university hospital.

Patients or participants: We reviewed 4,273 consecutive FFBs, including 2,493 bronchoalveolar lavages and 173 transbronchial biopsy procedures.

Interventions: None.

Results: Most (52%) FFBs were performed for obtaining lower respiratory tract samples for evaluation of suspected infection. An additional 17% were performed to evaluate an abnormality seen on chest radiograph. The most common therapeutic indication was removal of retained secretions in 8% of FFBs. The mortality rate was 0%, and the frequency of major and minor complications was 0.5% and 0.8%, respectively. The incidence of major complications secondary to transbronchial biopsy was 6.8%.

Conclusions: Flexible fiberoptic bronchoscopy can be performed safely in a teaching hospital with appropriate preparation, supervision, and adherence to protocol.

MeSH terms

  • Bronchoscopy / adverse effects*
  • Humans
  • Retrospective Studies