Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules

Radiol Med. 2013 Oct;118(7):1071-81. doi: 10.1007/s11547-013-0965-4. Epub 2013 Jul 25.

Abstract

Purpose: The aim of this study was to analyse factors predicting the diagnostic accuracy of computed tomography (CT)-guided transthoracic fine-needle aspiration (TTFNA) for solid noncalcified, subsolid and mixed pulmonary nodules, with particular attention to those responsible for false negative results with a view to suggesting a method for their correction.

Materials and methods: From January 2007 to March 2010, we retrospectively reviewed the CT images of 198 patients of both sexes (124 males and 74 females; mean age, 70 years; range age, 44-90) used for the guidance of TTFNA of pulmonary nodules. Aspects considered were: lesion size and density, distance from the pleura, and lesion site. Multiplanar reformatted images (MPR) were retrospectively obtained in the sagittal and axial oblique planes relative to needle orientation.

Results: The overall diagnostic accuracy of TTFNA CT-guided biopsy was 86% for nodules between 0.7 and 3 cm, 83.3% for those between 0.7 and 1.5 cm, and 92% for those between 2 and 3 cm. Accuracy was 95.1% for solid pulmonary nodules, 84.6% for mixed nodules, and 66.6% for subsolid nodules. The diagnostic accuracy of CT-guided TTFNA in relation to the distance between the nodule and the pleural plane was 95.6% for lesions adhering to the pleura and 83.5% for central ones. The diagnostic accuracy was 84.2% for the pulmonary upper lobe nodules, 85.3% for the lower lobe and 90.9% for those in the lingula and middle lobe. In 75% of false negative and inadequate/insufficient cases the needle was found to lie outside the lesion, after reconstruction of the needle path by MPR.

Conclusions: The positive predictive factors of CT-guided TTFNA are related to the nodule size, density and distance from the pleural plane. The most common negative predictive factor of CT-guided TTFNA is the wrong position of the needle tip, as observed in the sagittal and axial oblique sections of the MPR reconstructions. The diagnostic accuracy of CT-guided TTFNA can therefore be improved by using the MPR technique to plan the needle path during the FNA procedure.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Fine-Needle*
  • Female
  • Humans
  • Lung Neoplasms / diagnostic imaging
  • Lung Neoplasms / pathology*
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiography, Interventional*
  • Retrospective Studies
  • Solitary Pulmonary Nodule / diagnostic imaging
  • Solitary Pulmonary Nodule / pathology*
  • Tomography, X-Ray Computed*