Abstract
OBJECTIVE: To identify the factors associated with the use of arterial blood gas (ABG) and pulse oximetry (PO) in the initial management of patients with community-acquired pneumonia (CAP) and arterial hypoxemia at presentation.
PARTICIPANTS: A total of 944 outpatients and 1,332 inpatients with clinical and radiographic evidence of CAP prospectively enrolled from 5 study sites in the United States and Canada.
ANALYSES: Separate multivariate logistic regression analyses were used to 1) compare measurement of ABG and PO within 48 hours of presentation across sites while controlling for patient differences, and 2) identify factors associated with arterial hypoxemia (PaO2 <60 mm Hg or SaO2 <90% for non-African Americans and <92% for African Americans) while breathing room air.
RESULTS: Range of ABG use by site was from 0% to 6.4% (P=.06) for outpatients and from 49.2% to 77.3% for inpatients (P<.001), while PO use ranged from 9.4% to 57.8% for outpatients (P<.001) and from 47.9% to 85.1% for inpatients (P<.001). Differences among sites remained after controlling for patient demographic characteristics, comorbidity, and illness severity. In patients with 1 or more measurements of oxygenation at presentation, hypoxemia was independently associated with 6 risk factors: age >30 years (odds ratio [OR], 3.2; 95% confidence interval [CI], 1.7 to 5.9), chronic obstructive pulmonary disease (OR, 1.9; 95% CI, 1.4 to 2.6), congestive heart failure (OR, 1.5; 95% CI, 1.0 to 2.1), respiratory rate >24 per minute (OR, 2.3; 95% CI, 1.8 to 3.0), altered mental status (OR, 1.6; 95% CI, 1.1 to 2.3), and chest radiographic infiltrate involving >1 lobe (OR, 2.2; 95% CI, 1.7 to 2.9). The prevalence of hypoxemia among those tested ranged from 13% for inpatients with no risk factors to 54.6% for inpatients with ≥3 risk factors. Of the 210 outpatients who had ≥2 of these risk factors, only 64 (30.5%) had either an ABG or PO performed. In the 48 outpatients tested without supplemental O2 with ≥2 risk factors 8.3% were hypoxemic.
CONCLUSIONS: In the initial management of CAP, use of ABG and PO varied widely across sites. Increasing the assessment of arterial oxygenation among patients with CAP is likely to increase the detection of arterial hypoxemia, particularly among outpatients.
Similar content being viewed by others
References
Fine MJ, Auble TE, Yealy DM, et al. A prediction rule to identify low-risk patients with community-acquired pneumonia. N Engl J Med. 1997;336:243–50.
Fine MJ, Smith MA, Carson CA, et al. Prognosis and outcomes of patients with community-acquired pneumonia: a meta-analysis. JAMA. 1995;274:134–41.
Bowton DL, Scuderi PE, Haponik EF. The incidence and effect of outcomes of hypoxemia in hospitalized medical patients. Am J Med. 1994;97:38–46.
Fine MJ, Smith DN, Singer DE. The hospitalization decision in patients with community-acquired pneumonia: a prospective cohort study. Am J Med. 1990;89:713–21.
American Thoracic Society. Guidelines for the initial management of adults with community-acquired pneumonia: diagnosis, assessment of severity, and initial antimicrobial therapy. Am Rev Respir Dis. 1993;148:1418–26.
Fine MJ, Stone RA, Singer DE, et al. Processes and outcomes of care for patients with community-acquired pneumonia: results from the Pneumonia Patient Outcomes Research Team study. Arch Intern Med. 1999;159:970–80.
Meehan TP, Fine MJ, Krumholz HM, et al. Quality of care, process, and outcomes in elderly patients with pneumonia. JAMA. 1997;278:2080–4.
Zeballos RJ, Weisman IM. Reliability of non-invasive oximetry in black subjects during hypoxemia and exercise. Am Rev Respir Dis. 1991;144:1240.
Albaum M, Hill LC, Murphy M, et al. Interobserver reliability in assessment of chest radiograph in diagnosis of community-acquired pneumonia. Chest. 1996;110:343–50.
Summers RL, Anders RM, Woodward LH, Jenkens AK, Galli RL. Effect of routine pulse oximetry measurements on ED triage classification. Am J Emerg Med. 1998;16:5–7.
Mower WR, Sachs C, Nicklin EL, Baraff LJ. Pulse oximetry as a fifth pediatric vital sign. Pediatrics. 1997;99:681–6.
Sinex JE. Pulse oximetry: principles and limitations. Am J Emerg Med. 1999;17:59–67.
Jensen LA, Onyskiw JE, Prassad NG. Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults. Heart Lung. 1998;7:387–408.
Barker SJ, Shah NK. Effects of motion on the performance of pulse oximeters in volunteers. Anesthesiology. 1996;85:774–81.
Lindberg LG, Lennmarken C, Vegfors M. Pulse oximetry—clinical implications and recent technical developments. Acta Anaesthiol Scand. 1995;39:279–87.
Schmidt GA, Hall JB, Wood LDH. Ventilatory failure. In: Murray JF, Nadel JA, eds. Textbook of Respiratory Medicine. Philadelphia, Pa: WB Saunders; 1994.
Author information
Authors and Affiliations
Corresponding author
Additional information
Support for data collection was obtained from the Agency for Health Care Policy and Research (RO1 HSO6468) as part of the Pneumonia Patient Outcomes Research Team (PORT) Project. Partial grant support for data analysis was provided by Nellcor Puritan Bennett. Dr. Levin was funded by the University of Pittsburgh School of Medicine Alumni Association. Dr. Fine was supported in part as a Robert Wood Johnson Foundation Faculty Scholar.
Rights and permissions
About this article
Cite this article
Levin, K.P., Hanusa, B.H., Rotondi, A. et al. Arterial blood gas and pulse oximetry in initial management of patients with community-acquired pneumonia. J GEN INTERN MED 16, 590–598 (2001). https://doi.org/10.1046/j.1525-1497.2001.016009590.x
Issue Date:
DOI: https://doi.org/10.1046/j.1525-1497.2001.016009590.x