The role of the peak flow meter in the diagnosis and management of asthma
References (70)
- et al.
Perception of asthma
Lancet
(1976) - et al.
Physiologic correlates of airway collapse in chronic airflow obstruction
Chest
(1984) - et al.
Therapeutic and investigational evaluation of asthmatic children
J Allergy
(1968) - et al.
Comparison of PEFR and FEV1 in patients with varying degrees of airway obstruction: effect of modest altitude
Chest
(1989) - et al.
Significance of intraindividual changes in maximum expiratory flow volume and peak expratory flow measurements
Chest
(1982) - et al.
Pulmonary monitor for assessment of airways obstruction
Lancet
(1976) - et al.
An assessment of three portable peak flow meters
Chest
(1982) - et al.
Can patients keep their own peak-flow records reliably?
Lancet
(1979) - et al.
Fungal contamination of mini peak flow meters
Respir Med
(1989) - et al.
Characteristics and prognostic value of morning dipping of peak expiratory flow rate in stable asthmatic subjects
Chest
(1985)
Validation of morning dip of peak expiratory flow as an indicator of the severity of nocturnal asthma
Chest
Use of peak expiratory flow rates to eliminate unnecessary arterial blood gases in acute asthma
Ann Emerg Med
Comparison of peak expiratory flow and FEV1 admission criteria for acute bronchial asthma
Ann Emerg Med
Emergency room assessment and treatment of patients with acute asthma
Am J Med
Evaluation of the severity of asthma: patients versus physicians
Am J Med
Sensitivity and specificity of PC20 and peak expiratory flow rate in cedar asthma
J Allergy Clin Immunol
On observing patterns of airflow obstruction in chronic asthma
Br J Dis Chest
Improving the ability of peak expiratory flow rates to predict asthma
J Allergy Clin Immunol
Death from bronchial asthma
Chest
Asthma mortality: what have we learned [Postgrad course]?
J Allergy Clin Immunol
Mortality from asthma [CME article]
J Allergy Clin Immunol
Prevalence and treatment of asthma in the Michigan Medicaid population younger than 45 years, 1980–1986
J Allergy Clin Immunol
Chronic bronchitis, asthma, and pulmonary emphysema
Am Rev Respir Dis
Spirometric tests to diagnose suspected asthma
Am Rev Respir Dis
Comparison of normal and asthmatic circadian rhythms in peak expiratory flow rate
Thorax
Acute bronchial asthma: relations between clinical and physiologic manifestations
N Engl J Med
How mild is mild asthma?
Thorax
Home recording of peak expiratory flow rates and perception of asthma
Am J Dis Child
Use of peak expiratory flow rates in treating patients
Am J Dis Child
Training perception of airflow obstruction in asthmatics
Ann Allergy
Training perception of acute airflow obstruction
Ann Allergy
Bronchial responsiveness to histamine: relationship to diurnal variation of peak flow rate, improvement after bronchodilator, and airway calibre
Thorax
Effect of therapy on bronchial hyperresponsiveness in the long-term management of asthma
Clin Allergy
An evaluation of two inexpensive instruments for assessing airway flow
Ann Allergy
Cited by (81)
Optical fiber flowmeter based on graphene oxide coated michelson interferometer
2023, Sensors and Actuators A: PhysicalPeak expiratory flow, breath rate and blood pressure in adults with changes in particulate matter air pollution during the Beijing Olympics: A panel study
2014, Environmental ResearchCitation Excerpt :Peak expiratory flow is a direct measurement of the airway obstruction and lung function, and it has been used to evaluate the effects of different factors, including medical treatment and air pollution exposure, on airway caliber. The peak expiratory flow measurements at baseline in the studied population were 418 L/min for men and 292 L/min for women, which were lower than the normal range for both men (500–700 L/min) and women (380–500 L/min)(Cross and Nelson, 1991). Long-term exposure to polluted air may have resulted in the poor status of the airways and explains the relative low baseline peak expiratory flow.
Chapter 5 Biomarkers Related To Aging In Human Populations
2008, Advances in Clinical ChemistryCitation Excerpt :Peak expiratory flow (PEF) monitoring has been used as an objective measure of airflow obstruction. The normal range of PEF is 500–700 liter/min for men and 380–500 liter/min for women [330] but what is regarded as normal varies with differences in height and weight [331]. Studies have shown that PEF is related to mortality [332] and physical and cognitive functioning [333].
Agreement between pneumotachograph and PiKo-1 measurements of PEF and FEV<inf>1</inf>
2006, Archivos de Bronconeumologia