Table 1

Main results of British Thoracic Society hospital oxygen audits in 2008 and 2010

YearNumber of hospitalsNumber of patientsNumber of wardsOn oxygen (%)*Oxygen prescribed (%)Drug rounds signed (%)Oximetry recorded (%)§Correct delivery system (%)
20089914 83071217.532 (10)59447
20109022 017102615.556 (41)169959
  • * Patients using oxygen on the day of the audit.

  • Patients using oxygen who had a valid prescription or written order (and those with a prescription with target range).

  • Drug rounds on which oxygen was signed for (if patient on oxygen).

  • § Observation rounds during which oximetry was documented.

  • Patients using the exact oxygen delivery system specified for them.