Abstract P86 Table Procedure data, sensitivity and complication rates of patients undergoing FNA and CNB of pulmonary lesions
FNANon-coaxial CNBCoaxial CNB
No of procedures304921
Median number of samples (range)2 (1–8)3 (1–8)3 (0–6)
Mean lesion size (range)29 mm (18–71)51 mm (14–129)38 mm (8–110)
Mean distance from pleura (range)26 mm (10–62)8 mm (2–52)15 mm (1–63)
No of procedures traversing lung18 (60%)14 (28%)10 (50%)
No of procedures traversing emphysematous or fibrotic lung8 (27%)7 (14%)5 (25%)
Positive diagnosis243919
Sensitivity80%80%90%
Immediate pneumothorax visible on CT (%)12 (40%)9 (18%)7 (35%)
Admission for extended observation or chest drain2 (7%)1 (2%)1 (5%)
Evidence of haemorrhage on CT immediately post-procedure8 (27%)8 (16%)9 (45%)
Haemoptysis001
  • CNB, cutting needle biopsy; CT, computed tomography; FNA, fine-needle aspiration.