Table 2

Mean (SD) values for indices from the eight subjects who underwent simulated altitude in a hypobaric chamber under normoxic and hypoxic conditions.

CodeMean (SD)p value
FVC=forced vital capacity; FEV1=forced expiratory volume in 1 second; PEF=peak expiratory flow; α175%=first moment truncated at 75% of FVC; MEF30%=maximum expiratory flow with 30% of FVC still to be expired; MP30%=ratio of MEF30% on maximum flow loop divided by MEF30% from partial loop; LDS=log dose slope of index; code 1=sea level; 2=normoxic hypobaria; 3=hypoxic hypobaria. *p<0.05 (Friedman non-parametric test with Bonferroni correction).
FVC15.46 (0.95)0.22
25.26 (0.84)
35.28 (0.88)
FEV114.25 (0.58)0.69
24.20 (0.51)
34.30 (0.55)
PEF18.74 (1.26)0.002*
210.48 (1.31)
310.40 (1.39)
α175%10.33 (0.06)0.002*
20.28 (0.06)
30.28 (0.06)
MEF30%12.43 (0.52)0.04
22.39 (0.61)
32.61 (0.69)
MP30%10.97 (0.14)1.0
21.02 (0.19)
30.99 (0.18)
LDSFEV110.66 (0.40)0.37
20.51 (0.61)
30.63 (0.45)
LDSα175%10.77 (0.52)0.88
20.91 (0.34)
30.72 (0.51)
LDSMEF30%11.01 (0.32)0.45
20.85 (0.41)
31.11 (0.39)