Table 4

Association between atopy measured by skin test reaction and specific serum IgE

Negative (%) Positive (%) OR (95% CI)
Skin test ⩾3 mm more than control with corresponding allergen:
Specific mite IgE4-150 73/305 (23.9)19/36 (52.8)3.55 (1.73 to 7.30)
Specific cockroach IgE48/325 (14.8)9/22 (40.9)4.00 (1.59 to 10.0)
Specific cat IgE25/324 (7.7)4/23 (17.4)2.52 (0.79 to 8.02)
Any skin test 3 mm more than control:
Specific mite IgE4-150 59/257 (23.0)33/84 (39.3)2.17 (1.27 to 3.70)
Specific cockroach IgE34/261 (13.0)23/86 (26.7)2.44 (1.33 to 4.47)
Specific cat IgE18/261 (6.9)11/86 (12.8)1.98 (0.89 to 4.40)
  • 4-150  Mite IgE performed in 341 blood samples.