Table 4

Effect of specific resistances on ventilatory function. All results are relative to zero resistance

Percentage fall in ventilatory function (95% CI)
R =1.5 cm H2O/l/ sR =2.5 cm H2O/l/sR =3.5 cm H2O/l/s
FVC1.5 (0.8 to 2.3)2.6 (1.4 to 3.8)3.6 (1.9 to 5.3)
FEV1 1.9 (1.0 to 2.8)3.1 (1.7 to 4.6)4.4 (2.4 to 6.4)
PEF6.9 (5.4 to 8.3)11.5 (9.1 to 13.9)16.0 (12.7 to 19.4)
  • CI = confidence interval; R = breathing circuit resistance.