Humidifiers: the use of biocides and lung disease
Free
  1. C A C Pickering
  1. Correspondence to Professor C A C Pickering, North West Lung Research Centre, Wythenshawe Hospital, Manchester M23 9LT, UK; tony.pickering{at}manchester.ac.uk, cacgp{at}btinternet.com

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Over the last two decades several publications have reported outbreaks of interstitial lung disease caused by inhalational exposure to a chemical, usually at work, but occasionally in a domestic situation. These outbreaks frequently follow a change in formulation, which may be minor,1 of a chemical already being used in the workplace, or a change in process leading to its aerosolisation.

In 2006, paediatricians in South Korea became aware of a severe, rapid-onset interstitial pneumonitis in young children and infants; the disease responded very poorly to treatment, and mortality rates were close to 50%.2 Its seasonal presentation, with most cases presenting in the spring, raised the possibility of an infective aetiology; hypersensitivity pneumonitis was also considered. The failure to find any microbiological evidence for the former, and the distinct clinical and pathological features that distinguished it from the latter led to the consideration of other hypotheses. As a result, the Korean Centre for Disease Control set up a series of case-control studies designed to examine a wide variety of alternative environmental explanations. In early 2013, the findings of a small (n=16) study of affected children were published3; intriguingly, they indicated that all the cases, but just a third of the matched controls, had exposure to disinfectant used in domestic humidifiers, producing an OR of 2.73.

The epidemic in adults from the same country is described4 alongside the corresponding epidemiological investigation.5 As with the children, there was a very strong seasonal pattern to disease incidence and a clear clustering within families with an apparent predilection for pregnant or recently delivered women; 11 of the 15 female admissions were either pregnant or in the postpartum period. The tissue response was one of progressive, non-granulomatous, inflammation and, again, the disease appeared to have a rapid onset, was resistant to treatment and had a high mortality with five deaths; four patients survived following transplantation, and just two following conventional treatment. The epidemiological study5 established to examine a range of indoor environmental factors, recruited 18 cases carefully matched to 121 hospital controls. The results again identified humidifier detergent as the likely cause of the outbreak, but in this case with an extraordinarily high, adjusted OR of 53.01 (95% CI 6.33 to 444.17); it is not clear whether the apparent susceptibility of young women was related to the state of pregnancy or, perhaps more likely, to an increased exposure to biocide in the home. As a consequence of these findings, biocide detergents were withdrawn from the market in 2011; subsequently, there have been no further new cases reported.

South Korean winters and spring tend to be cold and dry with an average relative humidity of 60–65%. The use of home humidifiers is common there, particularly to relieve respiratory symptoms and dry skin. In a questionnaire survey of pregnant women in three areas of the country, 45% reported using humidifiers in December or January, in most cases for long periods of the day.6 The first biocide for domestic humidifiers was introduced in South Korea in 1994, CMIT/MIT (chloromethylisothiazol/methylisothiazol), and was followed in 2000 by PHMG-phosphate (polyhexamethylene guanidine phosphate), most commonly used by the patients described here, and in 2009 by PGH (oligoethoxyethyl guanidine chloride). The timing of the introduction of PHMG is consistent with the development of this epidemic. Subsequent animal experiments have revealed inflammatory changes, similar to those seen in human cases, in PHMG-exposed and PGH-exposed animals, but not in controls or those exposed to the CMIT/MIT. The guanides are good general-purpose bacteriocides, fungicides and algeocides having a high surface activity which disrupts the cell wall and cytoplasm of a wide range of micro-organisms; their major use is controlling microbiological growth in cooling systems.

The clinical picture described in these papers is unique. The exposure is to a ‘nonirritant’ chemical delivered in a particulate size capable of penetrating to bronchiolar and alveolar level in the lungs. The domestic humidifiers mainly used by the patients in these papers were warm mist, ultrasonic, and warm mist and ultrasonic; a study from the Korean Center for Disease Control and Prevention7 reported that when humidifier disinfectants are added to distilled water and used in an ultrasonic nebuliser, nanoparticles of 30–80 nm are generated, consisting of PHMG and PGH.

Humidification systems are used mainly in occupational settings where a stable relative humidity is required. They are used widely in a variety of industries including textiles, printing, timber, tobacco, cold stores, data centres, offices and automobile production. In the past, methods of cold water humidification included spraying water into incoming air, dripping water through a fibre mesh through which incoming air is forced, a spinning disc method in which a stream of water is trained against a rotating blade which atomises and blows it out of the humidifier, or the ultrasonic nebulisation of water into incoming air. The three former methods have largely now been discontinued, microbiological growth in static water proving difficult to control even with the use of a biocide.8 Microbial growth in workplace humidification systems has been reported to have caused cases of occupational asthma9 extrinsic allergic alveolitis10 and humidifier fever.11

The water supply to an ultrasonic nebuliser used in the workplace is directly from the mains, avoiding the presence of static water and, thus, the necessity of biocides. In the domestic setting, an ultrasonic nebuliser will have had a water supply coming from a small tank which, if not cleaned regularly, will develop microbial growth. In this outbreak, nebulisers were run with biocide in the water rather than it being used to clean the tank, a practise that was long ago deemed likely to be hazardous.12 Bronchial asthma13 as well as extrinsic allergic alveolitis14 have been described as a result of microbiological contamination of home humidifiers. In Western Europe, the use of home humidifiers is rare; rather, with the introduction of ‘tight’ buildings, the chief problem is in preventing high levels of humidity occurring in the home.

It is clearly necessary to keep home humidifiers clean, but running them with biocide detergents in the water is contraindicated. The tragedy of the Korean epidemic is a reminder of the importance of a full evaluation of the toxicity of chemical inhalants in the home. In this instance, the intended use of the biocides involved only dermal contact and possible ingestion and, therefore, was exempt from the submission of inhalation toxicology data. The use of these chemicals was then extended to humidifiers without recognition that this change in exposure route might cause significant health effects.