Article Text

PDF

Pulmonary vascular disease
P9 Determining the appropriate D-dimer cut-off to exclude pulmonary emboli in an ambulatory care setting using different thresholds based on pre-test probability
  1. R M Ladwa,
  2. E Bailie,
  3. Y Vali,
  4. R H Green,
  5. J A Bennett,
  6. C M Free
  1. University Hospitals of Leicester, Leicester, UK

Abstract

Introduction Currently the same threshold value is used to identify a positive D-dimer result for all patients presenting to our ambulatory clinic with suspected pulmonary emboli (PE). It has been suggested that adjusting the threshold value according to the pre-test probability would exclude PE in more patients than using the same cut-off point regardless of clinical probability.

Methods Data from 362 consecutive patients presenting to the ambulatory PE clinic was collected. A pre-test probability of PE was recorded for all patients and those with a high pre-test probability had radiological investigations. Patients with a low or intermediate pre-test probability had a latex agglutination D-dimer test. If this result was =0.5 μg/ml they had further investigations, otherwise they were discharged. The diagnosis of PE was made if a VQ scan showed ventilation/perfusion mismatch or CTPA report demonstrated PE. Receiver operating characteristic curve analysis was performed separately for patients with low and intermediate probability and the optimum cut-off value to exclude PE determined. Sensitivity, specificity, negative predictive value and positive predictive value for different cut-off points were determined.

Results 362 patients were included in the analysis, 207 (57%) had low, 129 (36%) intermediate and 26 (7%) high pre-test probability. Prevalence of PE was 2% in the low probability group, 14% in the intermediate probability group and 42% in the high probability group. No patients with a D-dimer of <0.5 μg/ml who were discharged without further tests have re-presented with similar symptoms. In the low pre-test probability group, a cut-off point of 1.07 improved the specificity from 64% to 89% while maintaining a sensitivity of 100% and negative predictive value of 100%. Analysis in patients in the intermediate risk group suggested that a cut-off of 0.5 μg/ml was appropriate. By adjusting the D-dimer threshold to >1.0 μg/ml in the low probability group, a further 53 patients could have been discharged home without need for radiological investigation.

Conclusion The diagnostic accuracy of D-dimer testing may be improved in patients with a low pre-test probability by adjusting the cut-off threshold.

Statistics from Altmetric.com

Request permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.