rss
Thorax 2009;64:463-465 doi:10.1136/thx.2009.114165
  • Editorial

Unintended consequences in the drive for zero

  1. Michael Klompas
  1. Dr Michael Klompas, Department of Ambulatory Care and Prevention, Harvard Medical School and Harvard Pilgrim Health Care, 133 Brookline Avenue, 6th Floor, Boston, MA 02215, USA; mklompas{at}partners.org

    With pressure mounting from legislators, insurers and consumer advocates to drive ventilator-associated pneumonia (VAP) rates to zero, the article by Conway Morris and colleagues (see page 516) in this issue of Thorax is a timely reminder that VAP rates are uncertain estimates rather than concrete measures of patient morbidity.1 Conway Morris and colleagues show that the reported VAP rate of an Intensive Care Unit (ICU) is heavily dependent upon its favoured diagnostic technique. ICUs that exclusively use bronchoalveolar lavage (BAL) to diagnose VAP are liable to report VAP rates that are 76% lower than those that exclusively use endotracheal aspirates. This laxity in the VAP definition confers a risk that some well-intended initiatives may decrease VAP rates yet provide little benefit to patients and perhaps even put some at risk.

    Conway Morris and colleagues base their estimate of varying VAP rates upon the comparative yield of simultaneous BAL and endotracheal aspirate cultures taken from 53 critically ill patients with clinical syndromes suggestive of pneumonia. All patients had radiographic infiltrates, pyrexia or an abnormal leucocyte count, and clinical signs of chest infection such as increased volume or purulence of sputum, crepitations and deterioration in oxygenation. In these patients, there was a clear step function in culture results: 89% of endotracheal aspirate qualitative cultures were positive (defined as any growth), 51% of endotracheal quantitative cultures were positive (defined as ≥106 colony-forming units (CFU)/ml), and 21% of BAL cultures were positive (defined as ≥104 CFU/ml).

    Each of these culture thresholds qualifies as VAP using the definitions of the Hospitals in Europe Link for Infection Control through Surveillance (HELICS) system. Consequently, depending upon one’s choice of diagnostic technique, measured VAP rates can vary fourfold. HELICS does assign different VAP codes to patients depending upon which culture technique and threshold was used …

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Thorax.
    View free sample issue >>

    Free archive
    The full back archive is now available for Thorax. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.