Thorax 2002;57:865-868 doi:10.1136/thorax.57.10.865
  • Original articles

Airway and systemic effects of hydrofluoroalkane fluticasone and beclomethasone in patients with asthma

  1. G P Currie,
  2. S J Fowler,
  3. A M Wilson,
  4. E J Sims,
  5. L C Orr,
  6. B J Lipworth
  1. Asthma & Allergy Research Group, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY, UK
  1. Correspondence to:
    Professor B J Lipworth, Asthma & Allergy Research Group, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY, UK;
    b.j.lipworth{at}dundee.ac.uk
  • Accepted 29 May 2002
  • Revised 8 May 2002

Abstract

Background: With the transition to hydrofluoroalkane-134a propellants in metered dose inhalers, it is important to consider the efficacy and safety profiles of formulations containing inhaled corticosteroids. We examined the airway and systemic effects of hydrofluoroalkane-134a fluticasone propionate (FLU-HFA) and beclomethasone dipropionate (BEC-HFA) at recommended labelled doses.

Methods: Twenty mild to moderate asthmatics were randomised in crossover fashion to receive 6 weeks of 500 μg/day followed by 1000 μg/day FLU-HFA and BEC-HFA. Measurements were made at baseline after placebo run in and washout, and after each randomised treatment. The primary airway outcome for benefit was the dose of methacholine provoking a fall in forced expiratory volume in 1 second (FEV1) of 20% or more (methacholine PD20) and for systemic adverse effects was overnight urinary cortisol/creatinine (OUCC).

Results: For mean responses, both doses of BEC-HFA and FLU-HFA produced significant improvements in PD20 compared with baseline. The improvement was not significantly greater with 1000 μg/day FLU-HFA versus BEC-HFA, a 1.69 fold difference (95% CI 0.94 to 3.04). Both doses of BEC-HFA but not FLU-HFA caused significant suppression of OUCC compared with baseline, with significantly (p<0.05) lower values at 1000 μg/day for BEC-HFA versus FLU-HFA (1.97 fold difference (95% CI 1.28 to 3.02)).

Conclusion: There was no difference in the airway and systemic effects in patients with mild to moderate asthma between FLU-HFA and BEC-HFA at a dose of 500 μg/day. At 1000 μg/day there was increased systemic bioactivity with BEC-HFA compared with FLU-HFA, without any gain in airway efficacy.

Footnotes

  • This study was supported by a University of Dundee anonymous grant and received no support from the pharmaceutical industry.

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Thorax.
View free sample issue >>

Free archive
The full back archive is now available for Thorax. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.