rss
Thorax 1980;35:181-185 doi:10.1136/thx.35.3.181
  • Research Article

Effect of positive end-expiratory pressure on intrapulmonary shunt at different levels of fractional inspired oxygen.

Abstract

In 10 patients undergoing ventilation, venous admixture was measured at different values of positive end-expiratory pressure (PEEP). The measurements were performed at the level of fractional inspired oxygen (FIO2) at which each patient was ventilated, and at FIO2=1. In patients ventilated at FIO2 between 0.21 and 0.3 venous admixture was not modified by PEEP, while in patients ventilated with FIO2 between 0.4 and 0.6, venous admixture decreased significantly (p less than 0.01). With FIO2=1, increased PEEP produced a reduction in venous admixture in all cases (p less than 0.05). These observations suggest that in patients similar to ours, PEEP does not reduce venous admixture at low levels of FIO2 (0.21--0.3), and the observed reduction with PEEP at FIO2=1 may be misinterpreted.

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.