Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of lung cancer patients

Michael Westhoff 1*, Patric Litterst 1, Lutz Freitag 1, Wolfgang Urfer 2, Sabine Bader 3 and Joerg Ingo Baumbach 3

1 Lung Clinic Hemer, Germany
2 Institute of Statistics,Technical University Dortmund, Germany
3 ISAS - Institute for Analytical Sciences, Germany

* To whom correspondence should be addressed. E-mail: michael.westhoff{at}lkhemer.de.

Accepted 20 November 2008


Abstract

Background: Analysis of exhaled breath, especially of volatile organic compounds (VOCs), is of increasing interest in the diagnosis of lung cancer. Compared to other methods of breath analysis, ion mobility spectrometry (IMS) offers a ten-fold higher detection rate of VOCs. By coupling the ion mobility spectrometer with a multi-capillary column as a pre-separation unit, IMS offers the advantage of an immediate two-fold separation of VOCs with visualisation in a three-dimensional chromatogram. The total analysis time is about 500 s compared to gas chromatography/mass spectrometry (GC/MS) of about 1 h. Therefore it seemed reasonable to test IMS in breath analysis.

Methods: In this pilot study 32 patients with lung cancer were subjected to a breath analysis by IMS. Their IMS-chromatograms were compared with those of 54 healthy controls. An IMS that was built for special clinical application was used to identify characteristic peaks of VOCs , which might be relevant for the diagnosis of lung cancer in exhaled air of 10 mL volume.

Results: By a combination of 23 peak regions within the IMS-Chromatogram, patients with lung cancer, including a patient with carcinoma in situ, were classified and differentiated from healthy persons with an error rate of 0.

Conclusion: Breath analysis by IMS can detect a discriminating combination of VOCs in lung cancer patients. By pattern recognition without the need for chemical analysis of the underlying VOCs, IMS has the potential to facilitate lung cancer diagnosis.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Relevant Article

Give me a sign, any sign
Peter J Mazzone
Thorax 2009 64: 737-738. [Extract] [Full Text] [PDF]

This article has been cited by other articles:

  • Mazzone, P. J (2009). Give me a sign, any sign. Thorax 64: 737-738 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Chest Medicine Jobs

Chest Medicine Jobs