Short report
Evaluation of pulsed dose oxygen delivery during exercise in
patients with severe chronic obstructive pulmonary disease
Academic Department
of Respiratory Medicine, St Bartholomew's and Royal London School of
Medicine and Dentistry, London Chest Hospital, Bonner Road, London E2
9JX, UK
Correspondence to: Dr J A Wedzicha.
Received 7 September 1998; Returned to authors 15 October 1998; Revised version received 12 November 1998; Accepted for publication 17 November 1998
BACKGROUND
Oxygen
conserving devices may lead to substantial increases in the duration of
oxygen provided. A study was undertaken to compare the performance of a
pulsed dose oxygen delivery (PDOD) system with continuous flow oxygen
or air during a maximal walking test.
METHODS
Fourteen
patients with chronic obstructive pulmonary disease (COPD) and arterial
oxygen desaturation on exercise (mean (SD) forced expiratory volume in
one second (FEV1) 0.83 (0.28) l, arterial oxygen pressure
(PaO2) 8.38 (1.24) kPa, arterial carbon
dioxide pressure (PaCO2) 5.95 (0.86) kPa) were
randomised to perform a walking test using air administered via a
cylinder or continuous flow oxygen at 2 l/min or by a PDOD system.
RESULTS
There
was no significant difference in the mean arterial oxygen saturation
(SaO2) using the PDOD system or with continuous flow oxygen (p = 0.33). Patients showed greatest desaturation whilst
walking with the air cylinder (SaO2 79.2 (8.59)%) which was significantly different from the desaturation with
both continuous flow oxygen (87.6 (5.85)%, p = 0.001) and PDOD (85.6 (7.36)%, p = 0.004). There was no significant difference between the
distance walked using oxygen delivered at 2 l/min by continuous flow
or via the PDOD (p = 0.72; CI 0.34 to 1.08). The mean (SD) distance walked on continuous flow oxygen (203.6 (106.1) m) and PDOD (207.9 (109.8) m) was significantly greater than the distance walked with the
air cylinder (188.6 (110.02) m); (1.12 fold increase in distance, CI
1.01 to 1.23, p = 0.02, and 1.14 fold increase in distance, CI 1.01 to
1.28, p = 0.03, respectively).
CONCLUSIONS
These
findings suggest that the pulsed dose oxygen conserving device was as
effective as continuous flow oxygen in maintaining arterial oxygen
saturation and that the use of this device was associated with similar
improvements in exercise tolerance to patients taking continuous flow
oxygen therapy.
© 1999 by Thorax
This article has been cited by other articles:
-
Bradley, J. M., Lasserson, T., Elborn, S., MacMahon, J., O'Neill, B.
(2007). A Systematic Review of Randomized Controlled Trials Examining the Short-term Benefit of Ambulatory Oxygen in COPD. Chest
131: 278-285
[Abstract] [Full Text] -
Jensen, G., Nielsen, H. B., Ide, K., Madsen, P. L., Svendsen, L. B., Svendsen, U. G., Secher, N. H.
(2002). Cerebral Oxygenation During Exercise in Patients With Terminal Lung Disease*. Chest
122: 445-450
[Abstract] [Full Text] -
Cuvelier, A., Nuir, J.-F., Chakroun, N., Aboab, J., Onea, G., Benhamou, D.
(2002). Refillable Oxygen Cylinders May Be an Alternative for Ambulatory Oxygen Therapy in COPD*. Chest
122: 451-456
[Abstract] [Full Text] -
Garrod, R, Paul, E A, Wedzicha, J A
(2000). Supplemental oxygen during pulmonary rehabilitation in patients with COPD with exercise hypoxaemia. Thorax
55: 539-543
[Abstract] [Full Text] -
COTES, J E
(1999). Pulsed dose oxygen delivery system. Thorax
54: 750a-750
[Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.