Development of OASYS-2: a system for the analysis of serial measurement of peak expiratory flow in workers with suspected occupational asthma.
Occupational Lung Disease Unit, Birmingham Heartlands Hospital, UK.
BACKGROUND: Serial peak expiratory flow (PEF) measurement is usually the most appropriate first step in the confirmation of occupational asthma. Visual assessment of the plotted record is more sensitive and specific than statistical methods so far reported. The use of visual analysis is limited by lack of widespread expertise in the methods. A computer assisted diagnostic aid (OASYS-2) has been developed which is based on a scoring system developed from visual analysis. This removes the requirement for an experienced interpreter and should lead to the more widespread use of the technique. METHODS: PEF records were collected from workers attending an occupational lung disease clinic for investigation of suspected occupational asthma and from workers participating in a study of respiratory symptoms in a postal sorting office. PEF records were divided into two development sets and two gold standard sets. The latter consisted of records from workers in which a final diagnosis had been reached by a method other than PEF recording. An experienced observer scored individual work and rest periods for the two development set PEF records; linear discriminant analysis was used to compare measurements taken from development set 1 records with visual scores. Two equations were produced which allowed prediction of scores for individual work or rest periods. The development set 2 was used to determine how these scores should be used to produce a whole record score. The first gold standard set was used to determine the whole record score which best separated those with and without occupational asthma. The second set determined the sensitivity and specificity of the chosen score. RESULTS: Two hundred and sixty eight PEF records were collected from 169 workers and divided into two development sets (81 and 60 records) and two gold standard sets (60 and 67 records). Linear discriminant analysis produced equations predicting the score for work periods incorporating five indices of PEF change and one for rest periods using seven indices. These equations correctly predicted the score for development set 1 work and rest periods on 61% of occasions (kappa = 0.47). The whole record score for development set 2 records, after weighting for definite or definitely no occupational effect, correlated with the visual score (correlation coefficient 0.86). Comparison with gold standard set 1 identified a cut off which proved to have a sensitivity of 75% and a specificity of 94% for an independent diagnosis of occupational asthma when applied to gold standard set 2. CONCLUSIONS: These results suggest that the sensitivity and specificity of analysing PEF records for occupational asthma using OASYS-2 approaches that of visual analysis, but it should be absolutely reproducible. The performance of OASYS-2 is more specific and approaches the sensitivity of other statistical methods of analysis. The evaluation of a large number of PEF records from workers exposed to different sensitising agents suggests that these results should be robust and should be repeatable in clinical practice.
This article has been cited by other articles:
-
Park, D., Moore, V. C., Burge, C. B. S. G., Jaakkola, M. S., Robertson, A. S., Burge, P. S.
(2009). Serial PEF measurement is superior to cross-shift change in diagnosing occupational asthma. Eur Respir J
34: 574-578
[Abstract] [Full Text] -
Moore, V. C., Jaakkola, M. S., Burge, C. B. S. G., Pantin, C. F., Robertson, A. S., Vellore, A. D., Burge, P. S.
(2009). PEF analysis requiring shorter records for occupational asthma diagnosis. Occup Med (Lond)
59: 413-417
[Abstract] [Full Text] -
Moore, V. C., Cullinan, P., Sadhra, S., Burge, P. S.
(2009). Peak expiratory flow analysis in workers exposed to detergent enzymes. Occup Med (Lond)
59: 418-423
[Abstract] [Full Text] -
Adewole, F., Moore, V. C., Robertson, A. S., Burge, P. S.
(2009). Diesel exhaust causing low-dose irritant asthma with latency?. Occup Med (Lond)
59: 424-427
[Abstract] [Full Text] -
Sauni, R., Kauppi, P., Helaskoski, E., Virtema, P., Verbeek, J.
(2009). Audit of quality of diagnostic procedures for occupational asthma. Occup Med (Lond)
59: 230-236
[Abstract] [Full Text] -
Moore, V. C., Jaakkola, M. S., Burge, C. B. S. G., Robertson, A. S., Pantin, C. F. A., Vellore, A. D., Burge, P. S.
(2009). A New Diagnostic Score for Occupational Asthma: The Area Between the Curves (ABC Score) of Peak Expiratory Flow on Days at and Away From Work. Chest
135: 307-314
[Abstract] [Full Text] -
Yates, B., De Soyza, A., Harkawat, R., Stenton, C.
(2008). Occupational asthma caused by Arabidopsis thaliana: a case of laboratory plant allergy. Eur Respir J
32: 1111-1112
[Abstract] [Full Text] -
Fishwick, D, Barber, C M, Bradshaw, L M, Harris-Roberts, J, Francis, M, Naylor, S, Ayres, J, Burge, P S, Corne, J M, Cullinan, P, Frank, T L, Hendrick, D, Hoyle, J, Jaakkola, M, Newman-Taylor, A, Nicholson, P, Niven, R, Pickering, A, Rawbone, R, Stenton, C, Warburton, C J, Curran, A D, British Thoracic Society Standards of Care Subcomm,
(2008). Standards of care for occupational asthma. Thorax
63: 240-250
[Full Text] -
Barber, C. M., Naylor, S., Bradshaw, L., Francis, M., Harris-Roberts, J., Rawbone, R., Curran, A., Fishwick, D., on behalf of the British Thoracic Society Research,
(2008). Facilities for investigating occupational asthma in UK non-specialist respiratory departments. Occup Med (Lond)
58: 71-73
[Abstract] [Full Text] -
Robertson, W, Robertson, A S, Burge, C B S G, Moore, V C, Jaakkola, M S, Dawkins, P A, Burd, M, Rawbone, R, Gardner, I, Kinoulty, M, Crook, B, Evans, G S, Harris-Roberts, J, Rice, S, Burge, P S
(2007). Clinical investigation of an outbreak of alveolitis and asthma in a car engine manufacturing plant. Thorax
62: 981-990
[Abstract] [Full Text] -
Chiry, S., Cartier, A., Malo, J.-L., Tarlo, S. M., Lemiere, C.
(2007). Comparison of Peak Expiratory Flow Variability Between Workers With Work-Exacerbated Asthma and Occupational Asthma. Chest
132: 483-488
[Abstract] [Full Text] -
Fishwick, D., Bradshaw, L., Henson, M., Stenton, C., Hendrick, D., Burge, S., Niven, R., Warburton, C., Rogers, T., Rawbone, R., Cullinan, P., Barber, C., Pickering, T., Williams, N., Ayres, J., Curran, A. D
(2007). Occupational asthma: an assessment of diagnostic agreement between physicians. Occup. Environ. Med.
64: 185-190
[Abstract] [Full Text] -
Dawkins, P., Robertson, A., Robertson, W., Moore, V., Reynolds, J., Langman, G., Robinson, E., Harris-Roberts, J., Crook, B., Burge, S.
(2006). An outbreak of extrinsic alveolitis at a car engine plant. Occup Med (Lond)
56: 559-565
[Abstract] [Full Text] -
Anees, W, Moore, V C, Burge, P S
(2006). FEV1 decline in occupational asthma. Thorax
61: 751-755
[Abstract] [Full Text] -
Medina-Ramon, M., Zock, J. P., Kogevinas, M., Sunyer, J., Basagana, X., Schwartz, J., Burge, P. S., Moore, V., Anto, J. M.
(2006). Short-term respiratory effects of cleaning exposures in female domestic cleaners. Eur Respir J
27: 1196-1203
[Abstract] [Full Text] -
Barraclough, R. M., Walker, J., Hamilton, N., Fishwick, D., Curran, A. D.
(2006). Sensitization to king scallop (Pectin maximus) and queen scallop (Chlamys opercularis) proteins. Occup Med (Lond)
56: 63-66
[Abstract] [Full Text] -
Nicholson, P J, Cullinan, P, Newman Taylor, A J, Burge, P S, Boyle, C
(2005). Evidence based guidelines for the prevention, identification, and management of occupational asthma. Occup. Environ. Med.
62: 290-299
[Abstract] [Full Text] -
Miller, M R
(2005). The PEF data plot: planning to get the message. Thorax
60: 91-92
[Full Text] -
Reddel, H K, Vincent, S D, Civitico, J
(2005). The need for standardisation of peak flow charts. Thorax
60: 164-167
[Abstract] [Full Text] -
Girard, F., Chaboillez, S., Cartier, A., Cote, J., Hargreave, F. E., Labrecque, M., Malo, J.-L., Tarlo, S. M., Lemiere, C.
(2004). An Effective Strategy for Diagnosing Occupational Asthma: Use of Induced Sputum. Am. J. Respir. Crit. Care Med.
170: 845-850
[Abstract] [Full Text] -
Anees, W., Gannon, P.F., Huggins, V., Pantin, C.F.A., Burge, P.S.
(2004). Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma. Eur Respir J
23: 730-734
[Abstract] [Full Text] -
Gautrin, D., Newman-Taylor, A.J., Nordman, H., Malo, J-L.
(2003). Controversies in epidemiology of occupational asthma. Eur Respir J
22: 551-559
[Abstract] [Full Text] -
Baldwin, D R, Gannon, P, Bright, P, Newton, D T, Robertson, A, Venables, K, Graneek, B, Barker, R D, Cartier, A, Malo, J-L, Wilsher, M, Pantin, C F A, Burge, P S
(2002). Interpretation of occupational peak flow records: level of agreement between expert clinicians and Oasys-2. Thorax
57: 860-864
[Abstract] [Full Text] -
Thickett, K.M., McCoach, J.S., Gerber, J.M., Sadhra, S., Burge, P.S.
(2002). Occupational asthma caused by chloramines in indoor swimming-pool air. Eur Respir J
19: 827-832
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.